Rain Bird PGA Valve Size and Metric Pressure-Loss Reference

Rain Bird PGA inch valve sizes with metric pressure-loss data

This reference presents Rain Bird's published metric pressure-loss data for the 100-PGA, 150-PGA and 200-PGA valves. Globe and angle configurations are shown separately because the flow path changes the loss through the valve.

The figures are a component reference. They do not replace a complete hydraulic calculation for the main, laterals, fittings, elevation, valves and operating sprinklers.

This page follows normal trade convention: the nominal solenoid-valve size remains in inches, while flow is shown in m³/h and pressure loss in bar. The l/min column is retained as a secondary check against the manufacturer data.

Models and controlled sources

  • Models: Rain Bird 100-PGA, 150-PGA and 200-PGA
  • Configurations: globe and angle
  • Data: flow in cubic metres per hour and litres per minute, with pressure loss in bar
  • Pressure-loss source: Rain Bird PGA Series pressure-loss chart, created 21 September 2020
  • Technical specification: Rain Bird PGA Series Valves, revision 2/22, D38529PEO
  • Current model check: Rain Bird PGA Series product page checked 6 September 2026

View Rain Bird's current PGA Series product page

Open Rain Bird's PGA pressure-loss chart

Open Rain Bird's PGA technical specification

Published metric pressure-loss table

Pressure loss is shown in bar. Cells marked “Not published” are blank in Rain Bird's source chart and have not been calculated or inferred.

On a phone: swipe left and right across the table to see every column.

Rain Bird PGA valve pressure loss by flow, valve size and globe or angle configuration
Flow
(m³/h)
Flow
(l/min)
100-PGA, 1 inch 150-PGA, 1.5 inch 200-PGA, 2 inch
Globe
(bar)
Angle
(bar)
Globe
(bar)
Angle
(bar)
Globe
(bar)
Angle
(bar)
0.5 7.6 0.35 0.30 Not published Not published Not published Not published
1.2 20 0.38 0.35 Not published Not published Not published Not published
3 50 0.41 0.38 Not published Not published Not published Not published
6 100 0.43 0.38 0.10 0.07 Not published Not published
9 150 0.48 0.51 0.22 0.14 0.08 0.07
12 200 Not published Not published 0.38 0.23 0.12 0.07
15 250 Not published Not published 0.61 0.36 0.17 0.10
18 300 Not published Not published 0.86 0.51 0.24 0.13
21 350 Not published Not published 1.16 0.70 0.33 0.18
24 400 Not published Not published Not published Not published 0.43 0.23
27 450 Not published Not published Not published Not published 0.54 0.30
30 500 Not published Not published Not published Not published 0.66 0.36
34 568 Not published Not published Not published Not published 0.83 0.45

Operating range and field-use notes

Rain Bird's current product page gives an operating-pressure range of 1.04 to 10.4 bar and a flow range without the PRS-D option of 0.45 to 34.05 m³/h. The PRS-D option has a published flow range of 1.14 to 34.05 m³/h and regulates outlet pressure up to 6.9 bar.

The source documents use slightly different rounded minimum metric flow values. The pressure-loss table above retains Rain Bird's published metric rows rather than silently changing them to match the rounded product-page range.

Confirm the installed model, inlet route and flow-control position before using the table. Allow separately for upstream and downstream pipe losses, fittings, elevation and dynamic demand. Manufacturer limits and compatible control equipment should be checked for the exact valve and solenoid on site.